XLPE insulation PVC sheathed steel tape armored power cable specification data sheet
Power Cable
Power cables are mainly used for power transmission and distribution purpose. It is an assembly of one or more individually insulated electrical conductors, usually held together with an overall sheath. The assembly is used for transmission and distribution of electrical power. Electrical power cables may be installed as permanent wiring within buildings, buried in the ground and run overhead or exposed.……Including: rubber cable, welding cable, URD cable, XLPE insulated power calbe etc.
Bare Overhead Conductor
Bare Overhead Conductors are used in overhead transmission and distribution network applications.They are also used for un-insulated hook ups, jumpers, grounding conductors and other applications. Our Conductors conform to ASTM, IEC, BS, BS EN and DIN standards.…… Including: AAC conductor, AAAC conductor, ACSR conductor, ACAR conductor, AACSR conductor, etc.
Aerial Bundled Cable
Aerial bundled cables (also aerial bundled conductors or simply ABC) are overhead power lines using several insulated phase conductors bundled tightly together, usually with a bare neutral conductor. Our abc calbe conform to ASTM, IEC, SANS standards.……Including: abc cables, cvered line wire, service drop wire etc.
Cross-linked polyethylene insulation PVC sheathed steel tape armored power cable specification, name and application:
Model | Name | Applicable occasions | |
Cu | Al | ||
YJV | YJLV | Cross-linked polyethylene insulated PVC sheathed power cable |
Laying in indoors, tunnel, cable trench and pipeline, can also be buried in the loose soil, cable is unable to bear external mechanical forces. Single core cable in magnetic duct is not permissible. |
YJY | YJLV | Cross-linked polyethylene insulated PE sheathed power cable | |
YJV22 | YJLV22 | Cross-linked polyethylene insulation PVC sheathed steel tape armored power cable | Directly buried laying ground, cable can bear a certain external mechanical forces, but unable to bear large pulling force. |
YJV23 | YJLV23 | Cross-linked polyethylene insulation PVC sheathed steel tape armored power cable |
The rated voltage of the cable, nominal cross section, and core number:
Model | Core number | Rated voltage (kV) | ||||||||
Cu | Al | 0.6/1 | 3.6/6 | 6/66/10 | 8.7/108.7/15 | 12/20 | 18/2018/30 | 21/35 | 26/35 | |
YJVYJY | YJLVYJLY | 1 | 1.5~400 | 25~500 | 25~500 | 25~500 | 35~500 | 50~500 | 50~500 | 50~500 |
3 | 1.5~300 | 25~300 | 25~300 | 25~300 | 35~300 | 50~300 | 50~300 | 50~300 | ||
2 | 1.5~150 | – | – | – | – | – | – | – | ||
3 1 | 4~400 | – | – | – | – | – | – | – | ||
3 2、4 1 | 50~240 | – | – | – | – | – | – | – | ||
5 | 1.5~35 | – | – | – | – | – | – | – | ||
YJV22YJV23 | YJLV22YJLV23 | 1 | 4~400 | 25~500 | 25~500 | 25~500 | 35~500 | 50~500 | 50~500 | 50~500 |
3 | 2.5~300 | 25~300 | 25~300 | 25~300 | 35~300 | 50~300 | 50~300 | 50~300 | ||
2 | 4~150 | – | – | – | – | – | – | – | ||
3 1 | 4~300 | – | – | – | – | – | – | – | ||
3 2、4 1 | 50~240 | – | – | – | – | – | – | – | ||
5 | 2.5~35 | – | – | – | – | – | – | – |
Leave a Reply