JYTOP XLPE POWER CABLE

phone

UL American standard galvanized steel tape armoured pvc coated mc industrial cables

Leave a Reply

Your email address will not be published. Required fields are marked *

  • Power Cable

    Power Cable

    Power cables are mainly used for power transmission and distribution purpose. It is an assembly of one or more individually insulated electrical conductors, usually held together with an overall sheath. The assembly is used for transmission and distribution of electrical power. Electrical power cables may be installed as permanent wiring within buildings, buried in the ground and run overhead or exposed.……Including: rubber cable, welding cable, URD cable, XLPE insulated power calbe etc.

  • Bare Overhead Conductor

    Bare Overhead Conductor

    Bare Overhead Conductors are used in overhead transmission and distribution network applications.They are also used for un-insulated hook ups, jumpers, grounding conductors and other applications. Our Conductors conform to ASTM, IEC, BS, BS EN and DIN standards.…… Including: AAC conductor, AAAC conductor, ACSR conductor, ACAR conductor, AACSR conductor, etc.

  • Aerial Bundled Cable

    Aerial Bundled Cable

    Aerial bundled cables (also aerial bundled conductors or simply ABC) are overhead power lines using several insulated phase conductors bundled tightly together, usually with a bare neutral conductor. Our abc calbe conform to ASTM, IEC, SANS standards.……Including: abc cables, cvered line wire, service drop wire etc.

  • UL American standard galvanized steel tape armoured pvc coated mc industrial cables
    Application and description:
    600V MC cables can be used for overhead installation, directly buried, laying on metal frame, cable bracket, groove or continuous rigid cable bracket. MC class requirements UL, used for the continuous working temperature 90 degrees wet / dry environment.
     
    Standards and certification:
     
    UL 44 – thermosetting material insulated wires and cables
     
    UL 1569 – coated metal cable
     
    IEEE 1202 – Flame test (70000 Btu/hr) of installed cable tray cable in commercial applications
     
    ICEA T-29-520 – cable vertical burning flame test s (210000 Btu/hr)
     
    ICEA S-95-658 (NEMA WC 70) Structural requirements
     
    Cable structure:
    Conductor: compact type concentric stranded copper conductor B class, meet ASTM B3,B8 and ICEA
    Insulation: flame retardant and moisture resistant crosslinked polyethylene (FRXLPE)
    Groundin wireg: concentric stranded copper conductor compact type B, followed by ASTM B3, B8
    Cabling way: filled between the insulation conductors, the gap add ground wire, and then by the adhesive tape around the package
    Armour: lap type galvanized steel strip armoring
    Sheath: flame retardant, resistant to daylight PVC (CPE/LSOH material optional)
    Color: black, other colors available.

    Technical parameter:

    Wire Conductor
    Inch/mm
    Nominal thickness of insulation
    Inch/mm
    Nominal insulation outside diameter
    Inch/mm
    Ground wire gauge Cable diameter
    Inch/mm
    Sheathed outside diameter
    Inch/mm
    Nominal thickness of sheath
    Inch/mm
    Nominal cable diameter
    Inch/mm
    Nominal cable weight
    Lbs/kft
    kg/km
    3 core
    8 0.139 3.53 0.045 1.14 0.232 5.89 10 0.510 12.95 0.720 18.29 0.050 1.27 0.820 20.83 511 761
    6 0.174 4.42 0.045 1.14 0.267 6.78 8 0.586 14.88 0.796 20.22 0.050 1.27 0.896 22.76 671 999
    4 0.221 5.61 0.045 1.14 0.314 7.98 8 0.685 17.40 0.895 22.73 0.050 1.27 0.995 25.27 867 1290
    2 0.277 7.04 0.045 1.14 0.370 9.40 6 0.808 20.52 1.018 25.86 0.050 1.27 1.118 28.40 1211 1802
    1 0.322 8.18 0.055 1.40 0.435 11.05 6 0.948 24.08 1.158 29.41 0.050 1.27 1.258 31.95 1458 2170
    1/0 0.362 9.19 0.055 1.40 0.475 12.07 6 1.034 26.26 1.244 31.60 0.050 1.27 1.344 34.14 1738 2586
    2/0 0.405 10.29 0.055 1.40 0.518 13.16 6 1.127 28.63 1.337 33.96 0.050 1.27 1.437 36.50 2046 3044
    3/0 0.454 11.53 0.055 1.40 0.567 14.40 4 1.233 31.32 1.443 36.65 0.050 1.27 1.543 39.19 2504 3727
    4/0 0.510 12.95 0.055 1.40 0.623 15.82 4 1.354 34.39 1.564 39.73 0.060 1.52 1.684 42.77 3131 4659
    250 0.558 14.17 0.065 1.65 0.691 17.55 4 1.501 38.13 1.711 43.46 0.060 1.52 1.831 46.51 3627 5397
    350 0.661 16.79 0.065 1.65 0.794 20.17 3 1.723 43.76 1.933 49.10 0.060 1.52 2.053 52.15 4800 7142
    500 0.790 20.07 0.065 1.65 0.923 23.44 2 2.002 50.85 2.212 56.18 0.060 1.5