Power cables are mainly used for power transmission and distribution purpose. It is an assembly of one or more individually insulated electrical conductors, usually held together with an overall sheath. The assembly is used for transmission and distribution of electrical power. Electrical power cables may be installed as permanent wiring within buildings, buried in the ground and run overhead or exposed.……Including: rubber cable, welding cable, URD cable, XLPE insulated power calbe etc.
Bare Overhead Conductors are used in overhead transmission and distribution network applications.They are also used for un-insulated hook ups, jumpers, grounding conductors and other applications. Our Conductors conform to ASTM, IEC, BS, BS EN and DIN standards.…… Including: AAC conductor, AAAC conductor, ACSR conductor, ACAR conductor, AACSR conductor, etc.
Aerial bundled cables (also aerial bundled conductors or simply ABC) are overhead power lines using several insulated phase conductors bundled tightly together, usually with a bare neutral conductor. Our abc calbe conform to ASTM, IEC, SANS standards.……Including: abc cables, cvered line wire, service drop wire etc.
50 mm armoured cable introduction:
-Conductor: Copper or aluminium conductor
-Insulation: Cross-linked polyethylene( XLPE or PVC)
-Color Identication: Brown, Grey, Black, Blue, Green/Yellow or others on request
-Filler: Polypropylene lament with lapped binding tape
-Inner Sheath: Polyvinyl chloride (Black)
-Armor: SWA steel wire armore (Remark: for single core the armore should be AWA)
-Remark: The cable can be of flame retardance, fire resistance and environment friendly or other property.
50mm Armoured Cable is one specific size of armoured cable, primarily used in large powered networks whilst also carrying power to a range of different powered devices. Although this cable can be used for domestic uses such as powering outdoor sheds and greenhouses as well as water features and outdoor lights, due to its size, it is commonly used in more industrial installations such as power stations and large construction sites.
Voltage grade is up to 35kv, cross-section area can be up to 400 sqmm (copper or aluminiun conductor). Conductor long-time operating temperature is 90 degrees. In short circuit, conductor highest temperature should be not more than 250 degrees.
For more details about 50 mm 2 core armoured cable: http://www.armoured-cable.net/50mm-Armoured-Cable/50mm-2-Core-Armoured-Cable.html
For more details about 50 mm 3 core armoured cable: http://www.armoured-cable.net/50mm-Armoured-Cable/50mm-3-Core-Armoured-Cable.html
For more details about 50 mm 4 core armoured cable: http://www.armoured-cable.net/50mm-Armoured-Cable/50mm-4-Core-Armoured-Cable.html
For more details about 50 mm 5 core armoured cable: http://www.armoured-cable.net/50mm-Armoured-Cable/5-core-swa-armoured-cable.html