JYTOP XLPE POWER CABLE

phone

How to do mc cable installation?

Leave a Reply

Your email address will not be published. Required fields are marked *

  • Power Cable

    Power Cable

    Power cables are mainly used for power transmission and distribution purpose. It is an assembly of one or more individually insulated electrical conductors, usually held together with an overall sheath. The assembly is used for transmission and distribution of electrical power. Electrical power cables may be installed as permanent wiring within buildings, buried in the ground and run overhead or exposed.……Including: rubber cable, welding cable, URD cable, XLPE insulated power calbe etc.

  • Bare Overhead Conductor

    Bare Overhead Conductor

    Bare Overhead Conductors are used in overhead transmission and distribution network applications.They are also used for un-insulated hook ups, jumpers, grounding conductors and other applications. Our Conductors conform to ASTM, IEC, BS, BS EN and DIN standards.…… Including: AAC conductor, AAAC conductor, ACSR conductor, ACAR conductor, AACSR conductor, etc.

  • Aerial Bundled Cable

    Aerial Bundled Cable

    Aerial bundled cables (also aerial bundled conductors or simply ABC) are overhead power lines using several insulated phase conductors bundled tightly together, usually with a bare neutral conductor. Our abc calbe conform to ASTM, IEC, SANS standards.……Including: abc cables, cvered line wire, service drop wire etc.

  • MC cable is required to be installed in some locations for home electrical wiring and is often used when wiring outlets and lighting circuits. The installation of MC Cable must be according to applicable codes including the following guidelines.
     
    MC cable installation steps:
    Skill Level: Intermediate to Advanced
    Tools Required: Electricians Pouch of Hand Tools for Rough-In Wiring, Electric Drill and Auger Bits and Extension Cord.
    Estimated Time: Depends on the extent of the project, the type of construction and available access to the project area..
    Precaution: Any existing wiring in the immediate area that may interfere with the installation should be identified and turned OFF and Tagged.
    Notice: Installing additional electrical wiring should be done with a permit and be inspected.
     
    MC cable needs to be supported as follows:
    1.The same as when running Romex wiring.
    2.Secured or supported every 4 feet 6 inches.
    3.Secured with 8 inches of the box.
    4.Insert insulated bushing sleeves at each end of the cable.
     

    Pre:
    Next: Armoured cat5 cable - marine network armored cable