JYTOP XLPE POWER CABLE

phone

bs6724 cable – 600/1000V mica tape XLPE insulation, low smoke halogen free sheathed power cable (sin

Leave a Reply

Your email address will not be published. Required fields are marked *

  • Power Cable

    Power Cable

    Power cables are mainly used for power transmission and distribution purpose. It is an assembly of one or more individually insulated electrical conductors, usually held together with an overall sheath. The assembly is used for transmission and distribution of electrical power. Electrical power cables may be installed as permanent wiring within buildings, buried in the ground and run overhead or exposed.……Including: rubber cable, welding cable, URD cable, XLPE insulated power calbe etc.

  • Bare Overhead Conductor

    Bare Overhead Conductor

    Bare Overhead Conductors are used in overhead transmission and distribution network applications.They are also used for un-insulated hook ups, jumpers, grounding conductors and other applications. Our Conductors conform to ASTM, IEC, BS, BS EN and DIN standards.…… Including: AAC conductor, AAAC conductor, ACSR conductor, ACAR conductor, AACSR conductor, etc.

  • Aerial Bundled Cable

    Aerial Bundled Cable

    Aerial bundled cables (also aerial bundled conductors or simply ABC) are overhead power lines using several insulated phase conductors bundled tightly together, usually with a bare neutral conductor. Our abc calbe conform to ASTM, IEC, SANS standards.……Including: abc cables, cvered line wire, service drop wire etc.

  • British standard cable; for adopting thermosetting insulation and affected by fire exudes a small amount of smoke and corrosive gases 600/ 1000V and 1900/3300V armoured cable specification.
     
    Cross linked polyethylene (XLPE) insulation, polyvinyl chloride (PVC) sheath or low smoke halogen free sheath (LSHF) cables
     
    Application:
     
    The cable is suitable for certain areas where circuit integrity is critical in maintaining power supply. The cable is mainly used for emergency lighting, control and power circuit, power station, fire alarm system, underground tunnel, fire elevator, escalator, and high-rise building wiring cable.
     
    Fire protection standard:
     
    Line integrity IEC 60331-21; BS 6387 CWZ; DIN VDE 0472- 
    814(FE180); BS 8434-2 (120mins); BS 5839-1 Clause 26 2e; 
    CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); NF C32-070-2.3(CR1
    The route of applying mechanical shock integrity EN 50200(PH120); CEI 20-36/4-0
    Mechanical shock and water injection line integrity EN 50200
    System integrity Depends on the laying systems DIN 4102-12, E30
      Flame retardant (single vertical cable testing) EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; 
    VDE 0482-332-1 ; NBN C 30-004 (cat. F1); 
    NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*
      Reduce the spread of fire (vertical installation into cable test) EN 60332-3-24 (cat. C); IEC 60332-3-24; 
    BS EN 60332-3-24; VDE 0482-332-3; 
    NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; 
    DIN VDE 0482-266-2-4
      Halogen free IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1*
      No corrosive gases IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2*
      Minimum smoke release IEC 61034-1&2; EN 61034 -1&2; 
    DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*
    No poisonous gas NES 02-713; NF C 20-454

    600/1000V mica tape XLPE insulation, low smoke halogen free sheathed power cable (single core)Rated voltage:
    600/1000V
     
    Cable structure:
    Conductor: plain annealed copper wire, stranded wire accord with IEC (EN) 60228 class 2
    Fire protection layer: mica tape covered in crosslinked polyethylene composite.
    Inner sheath: in line with the 7655: BS thermoplastic low smoke halogen free composite LTS3 type.
    Armour: aluminum wire armoured
    Outer sheath: in line with the BS 7652 standard the thermoplastic plastic, low smoke halogen free composite LTS3 class
     
    Physical and thermal properties:
    Operating temperature range (fixed state): -30°C – 90°C
    Installation temperature range (movement state): -20°C – 50°C
    Minimum bending radius: 8 * OD
     
    The structural parameters:
     
    Conductor FFX300 1Z1Z1-R
    Nominal cross-sectional area The number of stranded wire and diameter Conductor diameter Insulation thickness Unarmoured
    Nominal diameter The nominal weight
    mm2 No./mm mm mm mm kg/km
    1.5 7/0.53 1.59 0.7 6.5 54
    2.5 7/0.67 2.01 0.7 6.8 67
    4 7/0.85 2.55 0.7 7.5 86
    6 7/1.04 3.12 0.7 8.1 110
    10 7/1.35 4.05 0.7 9.2 155
    16 7/1.70 5.1 0.7 10.2 220
    25 7/2.14 6.42 0.9 11.9 325
    35 19/1.53 7.65 0.9 13.2 425
    50 19/1.78 8.9 1 14.6 600
    70 19/2.14 10.7 1.1 16.6 820
    95 19/2.52 12.6 1.1 18.7 1100
    120 37/2.03 14.21 1.2 20.5 1350
    150 37/2.25 15.75 1.4 22.7 1640
    185 37.2.52 17.64 1.6 25.5 2040
    240 61/2.25 20.25 1.7 28.5 2650
    300 61/2.52 22.68 1.8 31.5 3260
    400 65/2.85 25.65 2 35.4 4130
    500 61/3.20 28.8 2.2 39 5200
    630 127/2.52 32.76 2.4 43.5 6600
    800 127/2.85 37.05 2.6 48.5 8300
    1000 127/3.20 41.6 2.8 53.5 10000