JYTOP XLPE POWER CABLE

phone

What is the difference between xlpe and pvc insulated cable?

Leave a Reply

Your email address will not be published. Required fields are marked *

  • Power Cable

    Power Cable

    Power cables are mainly used for power transmission and distribution purpose. It is an assembly of one or more individually insulated electrical conductors, usually held together with an overall sheath. The assembly is used for transmission and distribution of electrical power. Electrical power cables may be installed as permanent wiring within buildings, buried in the ground and run overhead or exposed.……Including: rubber cable, welding cable, URD cable, XLPE insulated power calbe etc.

  • Bare Overhead Conductor

    Bare Overhead Conductor

    Bare Overhead Conductors are used in overhead transmission and distribution network applications.They are also used for un-insulated hook ups, jumpers, grounding conductors and other applications. Our Conductors conform to ASTM, IEC, BS, BS EN and DIN standards.…… Including: AAC conductor, AAAC conductor, ACSR conductor, ACAR conductor, AACSR conductor, etc.

  • Aerial Bundled Cable

    Aerial Bundled Cable

    Aerial bundled cables (also aerial bundled conductors or simply ABC) are overhead power lines using several insulated phase conductors bundled tightly together, usually with a bare neutral conductor. Our abc calbe conform to ASTM, IEC, SANS standards.……Including: abc cables, cvered line wire, service drop wire etc.

  • xlpe and pvc insulated cable
    -> The difference between xlpe and pvc insulated cable:
     
    1. low voltage crosslinked polyethylene(XLPE) cable since the mid – ninety 's put into application, the development is rapid, the current has been occupied half of the share with polyvinyl chloride (PVC) cable. Compared with PVC cable, the XLPE cable has high load capacity, strong overload capacity, long service life (PVC cable under the good environment the thermal life is 20 years, while the XLPE cable is generally 40 years); PVC burning will release a large number of black smoke and toxic gases, and XLPE burning will not produce halogen toxic gases, the superiority of the cross-linked cable is known increasingly by various departments.
     
    2. Ordinary PVC wire and cable (insulation and sheath) combustion speed is quick, fueling the fire, 1 – 2 minutes can loss the capability of power supply, the combustion and decomposition release black smoke and can up to not see his hand, resulting in respiratory and evacuation difficulty. Even more serious is that during the combustion of PVC, will breakdown and release hydrogen chloride (HCl) and dioxins and other toxic corrosive halogen gas, is the main reason of fire death-dealing in the fire(occupy 80% of fire death factors), and dilute hydrochloric acid electric membrane attached to the electrical equipment, seriously degrade the equipment insulation performance and the formation of secondary disaster, which is difficult to remove.
     
    -> Electrical, mechanical, weatherability contrast table:
    Item

    polyvinyl chloride insulated cable

    (PVC insulated cables)

    Cross-linked polyethylene insulated cable

    (XLPE insulated cable)

    Long-term Working Temperature 70℃ 90℃
    Highest working temperature of short circuit 160℃ 250℃
    Carrying capacity(A) a 1.25a
    Dielectric constant(20℃,60Hz) 8 2.3
    Tensile strength(Mpa) 20 23
    Elongation(%) 100-400 450-600
    Volume resistivity(Ω·m) 1010-1013 1016~1018
    Dielectric loss tangent(20℃,60Hz) 0.04-0.12 0.0002-0.0003
    The breakdown field strength(MV/m) 20-35 35-50
    Brittleness temperature℃ -40 -60
    Softening temperature℃ 120 120
    Thermal conductivity(W/m·K) 0.15 0.48
    Water quantity(%) 0.8 <0.01
    Oxygen index 30 18
    Resistance to acid and alkali, and climate good ~ best best
    Whether containing halogen containing do not contain
    Toxicity index 15.01 1.77
    Cable diameter D 0.92D
    Service life (year) 20 30

    -> Toxicity index comparison table:
    Gas Gas concentrationCQ(ppm) Dangerous concentrationsCQ (ppm)
    Polyvinyl chloride (PVC) Crosslinked polyethylene (XLPE)
    CO 5525 1971 4000
    CO2 46300 125400 100000
    HCL 6173 0 500
    NO2 1.5 3.6 250
    SO2 3.25 1.8 400
    Toxicity index 15.01 1.77  

    Summary: cross linked polyethylene insulation cable in the electrical performance, heat resistance, physical and mechanical properties, resistance to climate and toxicity are better than PVC insulated cable.
     