JYTOP XLPE POWER CABLE

phone

16mm 2 core low-smoke non-halogen fire-resistant armoured cable

Leave a Reply

Your email address will not be published. Required fields are marked *

  • Power Cable

    Power Cable

    Power cables are mainly used for power transmission and distribution purpose. It is an assembly of one or more individually insulated electrical conductors, usually held together with an overall sheath. The assembly is used for transmission and distribution of electrical power. Electrical power cables may be installed as permanent wiring within buildings, buried in the ground and run overhead or exposed.……Including: rubber cable, welding cable, URD cable, XLPE insulated power calbe etc.

  • Bare Overhead Conductor

    Bare Overhead Conductor

    Bare Overhead Conductors are used in overhead transmission and distribution network applications.They are also used for un-insulated hook ups, jumpers, grounding conductors and other applications. Our Conductors conform to ASTM, IEC, BS, BS EN and DIN standards.…… Including: AAC conductor, AAAC conductor, ACSR conductor, ACAR conductor, AACSR conductor, etc.

  • Aerial Bundled Cable

    Aerial Bundled Cable

    Aerial bundled cables (also aerial bundled conductors or simply ABC) are overhead power lines using several insulated phase conductors bundled tightly together, usually with a bare neutral conductor. Our abc calbe conform to ASTM, IEC, SANS standards.……Including: abc cables, cvered line wire, service drop wire etc.

  • Low-smoke halogen-free fire-resistant armoured cable:
     
    Term interpretation:
    Low smoke: in the test conditions, test sample, the heat decomposition of the sample under the fire and release less smoke, in line with the provisions of the indicators.
    Low halogen: under specified test conditions, sample when burned, release of halogenated gases hydrogen gas content rarely, in line with the specified index properties.
    Flame retardant: under certain test condition, sample is burn, after removed from the fire, the flames spread only within the scope of the provisions, remnant spark or burning within the prescribed time self extinguishing characteristics.
     
    16mm 2 Core Armoured Cable16mm 2 Core Armoured Cable is one kind of electrical cable, which has 16mm cross-sectional diameter armoured cable.
     
    16mm 2 Core Armoured Cable structure:
    1.plain annealed stranded copper used for the conductors/cores;
    2.cross-linked polyethylene (XLPE) for the insulation;
    3.PVC (Polyvinyl Chloride) for both the bedding and sheathing;
    4.steel wire for the armour protecting;
    5.Voltage: 600V/1000V
     
    The steel wire armour  cable also provides a form of mechanical protection, which means that it has higher pulling loads making it suitable for being dispensed from large cable drums. As well as providing mechnical protection, it also ensures that the cable can withstand highly corrosive environments such as being installed underground as well as being attached to outdoor walls.
     
    16mm 2 Core Armoured Cable is used in a wide range of industries across the globe. Some examples of the most common are:
    – The transport industry
    – Railway industry
    – Underneath roads carrying mains electricity to buildings
    – Cable Ducting within warehouses.
     
    Execution standard:
    The enterprise standard is formulated in accordance with the standards of GB/T5023-2008, GB/Tl2706-2008, and its fire resistance is in line with the requirements of GB/Tl9666 class. Test of poisonous gas content and smoke density in cable burning accord with GB/T17650.2-98 and GB/T17651.2-98, smoke toxicity accord with GBl32 security level requirement.
     
    Usage characteristics:
    1, the long-term working temperature of the conductor is 70℃ and 90℃.
    2, the cable under the condition of 750℃-850℃, can maintain normal operation for more than 1.5 hours, as B grade fire. Under the condition of 950℃-1000℃, the cable can be maintained for 1.5 hours or more, as A grade fire.
    3, toxic gas content and smoke density test results comply with GB / T17650.2-98 and GB / T17651.2-98 requirements.
    4, smoke toxicity in accordance with the requirements of the GAl32 safety level.
     
    2 core low-smoke halogen-free fire-resistant armoured cable parameter:
     

    Nominal cross section

    mm2

    Conductor diameter mm

    Cable approximate diameter

    mm

    Cable approximate weight

    kg/km

    DW-NH(B)-YJE23

    DW-NH(A)-YJE23

    DW-NH(B)-YJE23

    DW-NH(A)-YJE23

    2×1.5

    2×2.5

    2×4

    2×6

    2×10

    2×16

    2×25

    2×35

    2×50

    2×70

    2×95

    2×120

    2×150

    2×185

    2×240

    2×300

    1.38

    1.78

    2.24

    2.76

    4.05

    5.10

    6.42

    7.56

    8.9

    10.7

    12.6

    14.2

    15.8

    17.6

    20.3

    22.7

    13.7

    14.5

    15.4

    16.4

    19.6

    21.7

    25.1

    27.4

    30.5

    35.1

    40.9

    44.7

    49.0

    53.8

    59.8

    64.8

    236

    275

    324

    388

    531

    695

    972

    1219

    1547

    2104

    3218

    3787

    4547

    5505

    6945

    8386

    Pre: