JYTOP XLPE POWER CABLE

phone

BS5467 single core awa cables – Cu/XLPE/AWA/LSZH Aluminum Wire Armoured Cable

Leave a Reply

Your email address will not be published. Required fields are marked *

  • Power Cable

    Power Cable

    Power cables are mainly used for power transmission and distribution purpose. It is an assembly of one or more individually insulated electrical conductors, usually held together with an overall sheath. The assembly is used for transmission and distribution of electrical power. Electrical power cables may be installed as permanent wiring within buildings, buried in the ground and run overhead or exposed.……Including: rubber cable, welding cable, URD cable, XLPE insulated power calbe etc.

  • Bare Overhead Conductor

    Bare Overhead Conductor

    Bare Overhead Conductors are used in overhead transmission and distribution network applications.They are also used for un-insulated hook ups, jumpers, grounding conductors and other applications. Our Conductors conform to ASTM, IEC, BS, BS EN and DIN standards.…… Including: AAC conductor, AAAC conductor, ACSR conductor, ACAR conductor, AACSR conductor, etc.

  • Aerial Bundled Cable

    Aerial Bundled Cable

    Aerial bundled cables (also aerial bundled conductors or simply ABC) are overhead power lines using several insulated phase conductors bundled tightly together, usually with a bare neutral conductor. Our abc calbe conform to ASTM, IEC, SANS standards.……Including: abc cables, cvered line wire, service drop wire etc.

  • single core awa cablesSingle Core XLPE/LSZH/AWA/LSZH Cable:
     
    Application:
    Single core 600/1000V XLPE insulated PVC sheathed, armoured power cable is mainly used in power stations, public transport systems, airports, petrochemical factories, hotels, hospitals, high-rise buildings etc.
     
    Specification:
    in accordance with BS5467
     
    Conductors: Stranded Class 2 Copper Conductors to BS6360
    Insulation: XLPE
    Inner Sheath: PVC
    Armoring:
    Single Core: Aluminum Wire Armored (AWA)
    MultiCore: Steel Wire Armored (SWA)
    Outer Sheath: Black PVC
    Voltage Rating: 600/1000 volts
    Temp. Rating: 90℃
    Core Colour: Brown
     
    Using features:
    1. Rated voltage: 600/1000V
    2. No. of core: Single core
    3. The highest allowed operating temperature of conductor for long-term working is 90℃. In short-circuit (Max. long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250℃.
    4. D.C. resistance of the conductor complies with the stipulations of 600/1000V, 3.6/6kV, 6/10kV(11kV), 12/20kV(24kV), 19/33kV, 26/35kV(35kV).
    5. The environment temperature should be no lower than 0℃ when lay. Otherwise it should be preheated.
    6. The cable is laid without horizontal drop limit.
    7. Working Frequency Voltage Test: 3.5 Uo/5min without puncture.
    8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.
    9. Minimum Bending Radius: 12D overall diameter(70mm2 -1000mm2)
     
    The structural parameters:
     
    Conductor FTX300 1RCZ1MZ1-R
    Core number/cross-sectional area Number of strands/Monofilament diameter Nominal thickness of insulation Nominal thickness of sheath Outside diameter UNDER shielding Outside diameter OVER inner sheath Armoured layer diameter Total nominal diameter Weight
    MM² NO./MM MM MM MM MM MM MM KG/KM
    1×70 19/2.14 1.1 1.8 15.2 17.6 20.1 23.9 1400
    1×95 19/2.52 1.1 1.8 17.1 19.5 22.0 25.8 1700
    1×120 37/2.03 1.2 1.8 19.0 20.8 24.0 27.8 2000
    1×150 37/2.25 1.4 1.8 21.0 22.8 26.0 29.8 2400
    1×185 37/2.52 1.6 1.8 23.2 25.0 28.2 32.0 2800
    1×240 61/2.25 1.7 1.9 26.1 27.9 31.1 35.1 3500
    1×300 61/2.52 1.8 2.0 28.7 30.5 33.7 37.9 4200
    1×400 61/2.85 2.0 2.1 32.5 34.3 38.3 42.7 5400
    1×500 61/3.20 2.2 2.2 36.0 37.8 41.8 46.4 6500
    1×630 127/2.52 2.4 2.3 40.4 42.2 46.2 51.0 8200
    1×800 127/2.85 2.6 2.5 45.5 47.3 52.3 57.5 10400
    1×1000 127/3.20 2.8 2.7 50.4 52.2 57.2 62.4 13000

    Electrical performance:
    Conductor operating temperature 90℃
    Surroundings 30℃
     

    Pre:
    Next: BS 5467 armoured cable 4 core - solid aluminium or copper conductor