    Power cables are mainly used for power transmission and distribution purpose. It is an assembly of one or more individually insulated electrical conductors, usually held together with an overall sheath. The assembly is used for transmission and distribution of electrical power. Electrical power cables may be installed as permanent wiring within buildings, buried in the ground and run overhead or exposed.……Including: rubber cable, welding cable, URD cable, XLPE insulated power calbe etc.

  • Bare Overhead Conductor

    Bare Overhead Conductor

    Bare Overhead Conductors are used in overhead transmission and distribution network applications.They are also used for un-insulated hook ups, jumpers, grounding conductors and other applications. Our Conductors conform to ASTM, IEC, BS, BS EN and DIN standards.…… Including: AAC conductor, AAAC conductor, ACSR conductor, ACAR conductor, AACSR conductor, etc.

  • Aerial Bundled Cable

    Aerial Bundled Cable

    Aerial bundled cables (also aerial bundled conductors or simply ABC) are overhead power lines using several insulated phase conductors bundled tightly together, usually with a bare neutral conductor. Our abc calbe conform to ASTM, IEC, SANS standards.……Including: abc cables, cvered line wire, service drop wire etc.

  • 3 core power cable
    Application:
     
    Three core cable design and distribution range is 3.8/6.6KV to 19/33KV, the frequency is 50Hz. Mainly used in the power supply station, indoor and outdoor pipelines, underground water and other places, as well as the industry, power station, power station cable installation.
     
    Standard:
     
    IEC 60502 Part 1 (1.8/3KV)
    IEC 60502 Part 2 (to 18/30KV 3.6/6KV)
     
    Structure:
     
    Conductor: plain annealed copper or aluminum conductor, with IEC 60228 (1 class and 2 class).
     
    Conductor shield: conductor shielding should be non metallic, and should include a semi conductive compound, semiconductor band used in the top of the semiconductor complex.
    The conductor shielding layer is applied to the three important extrusion process in the outer and the insulation shield. The conductor shielding layer is made of non metallic layer, and the semi conductive compound must be firmly adhered to the insulation, and all gaps are eliminated. Conductor shielding layer for 1.8/3KV – 3.6/6KV PVC, EPR/HEPR insulated cable is not necessary.
     
    Insulation: 1.8/3KV and 3.6/6KV cable is generally used in PVC insulation, can also use EPR/HEPR, XLPE insulation.
     
    Physical properties:
     
    Operating temperature: 70°C (PVC insulation), up to 90°C (XLPE or EPR insulation)
    Temperature range: -5 °C(PVC); -20 °C(PE).
    Short circuit temperature (the longest duration at short circuit is no more than 5S): 140-160 °C(PVC sheath);
     250 degree°C(PE sheath)
    Bending radius: 15D
     
    1.8/3 KV Three core Unarmoured cable and round steel wire armoured cable structure parameters (Um = 3.6 KV):
    Nominal cross-sectional area   Unarmoured cable Round steel wire armoured
    Nominal thickness of insulation The thickness of the copper strip Copper wire shielding area Nominal thickness of sheath Approximate diameter Approximate weight Nominal thickness of pads Thickness of the armor Sheath nominal thickness Approximate diameter Approximate weight
    Cu Al Cu Al
    mm2 mm mm mm2 mm mm kg/km mm mm mm mm kg/km
    10 2.0 0.1 16 1.8 23 650 460 1.2 1.6 1.8 28 1480 1290
    16 2.0 0.1 16 1.8 24 840 540 1.2 1.6 1.9 29 1720 1410
    25 2.0 0.1 16 1.8 26 1160 680 1.2 1.6 1.9 32 2130 1650
    35 2.0 0.1 16 1.8 29 1490 820 1.2 2.0 2.1 36 2810 2140
    50 2.0 0.1 16 1.9 32 1900 1000 1.2 2.0 2.2 39 3340 2450
    70 2.0 0.1 16 2.0 36 2580 1290 1.2 2.0 2.3 42 4200 2910
    95 2.0 0.1 16 2.2 40 3440 1640 1.3 2.5 2.4 47 5620 3820
    120 2.0 0.1 16 2.3 43 4220 1950 1.3 2.5 2.5 51 6580 4310
    150 2.0 0.1 25 2.4 46 5090 2290 1.4 2.5 2.7 54 7680 4870
    185 2.0 0.1 25 2.5 50 6240 2730 1.5 2.5 2.8 58 9060 5560
    240 2.0 0.1 25 2.7 56 8030 3430 1.6 2.5 3.0 64 11200 6600
    300 2.0 0.1 25 2.8 60 9890 4100 1.6 2.5 3.1 69 13590 7500
    400 2.0 0.1 35 3.1 68 12530 5150 1.8 3.15 3.4 78 17260 9880
    500 2.2 0.1 35 3.3 75.7 16680 7510 1.8 3.15 3.5 84.3 21780 13025
    630 2.4 0.1 35 3.5 84.9 21770 10040 1.8 3.15 3.8 94.6 27400 16050

    1.8/3 KV Three core flat steel wire armoured and double steel tape armoured cable structure parameters (Um = 3.6 KV):
      Flat steel wire armoured Double steel tape armoured
    Nominal cross-sectional area Nominal thickness of cushion layer Armoured size Sheathed nominal thickness Approximate diameter Approximate weight Nominal thickness of cushion layer Armoured size Sheathed nominal thickness Approximate diameter Approximate weight
    CU AL CU AL
    mm2 mm mm mm mm kg/km mm mm mm mm kg/km
    10 1.2 0.8 1.8 24.5 1245 1065 1.2 2 x 0.2 1.8 23.6 925 750
    16 1.2 0.8 1.8 27.1 1565 1280 1.2 2 x 0.2 1.8 26.2 1205 925
    25 1.2 0.8 1.8 29.7 1975 1525 1.2 2 x 0.2 1.9 29.0 1590 1145
    35 1.2 0.8 1.9 32.5 2420 1805 1.2 2 x 0.2 1.9 31.6 1985 1370
    50 1.2 0.8 2.0 35 2860 2080 1.2 2 x 0.2 2.0 34.1 2400 1605
    70 1.2 0.8 2.1 38.7 3685 2525 1.2 2 x 0.5 2.2 39.5 3570 2410
    95 1.3 0.8 2.2 42.9 4695 3080 1.3 2 x 0.5 2.3 43.7 4570 2950
    120 1.3 0.8 2.3 46.4 5650 3585 1.3 2 x 0.5 2.4 46.1 5510 3440
    150 1.4 0.8 2.4 49.6 6630 4085 1.4 2 x 0.5 2.6 50.6 6500 3955
    185 1.5 0.8 2.6 54.1 7990 4820 1.5 2 x 0.5 2.7 54.9 7825 4650
    240 1.6 0.8 2.7 59.2 10060 5790 1.6 2 x 0.5 2.8 60.0 9825 5600
    300 1.6 0.8 2.9 64.6 12230 6865 1.6 2 x0.5 3.0 65.4 12030 6660
    400 1.8 0.8 3.1 71.0 15200 8280 1.8 2 x 0.5 3.2 71.8 14970 8055
    500 1.8 0.8 3.3 79.5 19090 10255 1.8 2 x 0.8 3.5 80.5 18880 10035
    630 1.8 0.8 3.6 89.8 24400 12920 1.8 2 x 0.8 3.8 92.3 25070 13620
    3 core power cable
    3 core 3.8/6.6KV (Um=7.2KV)
    3 core 6/10KV (Um=12KV)
    3 core  8.7/15KV (Um=17.5KV)
    3 core 12/20KV (Um=24KV)
    3 core 18/30KV (Um=36KV)
    3 core 21/35KV (Um=42KV)
    3 core 26/35KV (Um=42KV)
    3 core rated current 1.8/3KV(Um=7.2 )KV to 26/35KV(Um=42KV)

    More detail: 3 core armoured cable carrying capacity list
     