JYTOP XLPE POWER CABLE

phone

How to select suitable high voltage cable type?

Leave a Reply

Your email address will not be published. Required fields are marked *

  • Power Cable

    Power Cable

    Power cables are mainly used for power transmission and distribution purpose. It is an assembly of one or more individually insulated electrical conductors, usually held together with an overall sheath. The assembly is used for transmission and distribution of electrical power. Electrical power cables may be installed as permanent wiring within buildings, buried in the ground and run overhead or exposed.……Including: rubber cable, welding cable, URD cable, XLPE insulated power calbe etc.

  • Bare Overhead Conductor

    Bare Overhead Conductor

    Bare Overhead Conductors are used in overhead transmission and distribution network applications.They are also used for un-insulated hook ups, jumpers, grounding conductors and other applications. Our Conductors conform to ASTM, IEC, BS, BS EN and DIN standards.…… Including: AAC conductor, AAAC conductor, ACSR conductor, ACAR conductor, AACSR conductor, etc.

  • Aerial Bundled Cable

    Aerial Bundled Cable

    Aerial bundled cables (also aerial bundled conductors or simply ABC) are overhead power lines using several insulated phase conductors bundled tightly together, usually with a bare neutral conductor. Our abc calbe conform to ASTM, IEC, SANS standards.……Including: abc cables, cvered line wire, service drop wire etc.

  • select suitable high voltage cable type
    1. according to the voltage level of the cable laying, location and operating environment, selection of cable insulation type (such as PVC and XLPE, rubber insulating oxide etc);
     
    2. According to the cable laying environment, selection of cable jacket protection (such as steel tape armour, steel wire armored, etc.);
     
    3. according to voltage level of cables, select the rated voltage of the cable;
     
    4. According to the cable loop rated current, selection of cable cross section.
     
    5. so-called 10kV cable selection does not consider the carrying capacity, is that the power system short-circuit current thermal stability value is relatively high, according to the thermal stable value selected the minimum section of cable has great (such as 180 mm2 or 240 mm square cross section), in this section of the load flow range, regardless of the size of the load current, all according to the thermal stability minimum cross section select cable.

    Pre:
    Next: Model selection of mining high voltage cables