JYTOP XLPE POWER CABLE

phone

bs5467 specification low voltage 3 core Cu/Al conductor armoured power cables

Leave a Reply

Your email address will not be published. Required fields are marked *

  • Power Cable

    Power Cable

    Power cables are mainly used for power transmission and distribution purpose. It is an assembly of one or more individually insulated electrical conductors, usually held together with an overall sheath. The assembly is used for transmission and distribution of electrical power. Electrical power cables may be installed as permanent wiring within buildings, buried in the ground and run overhead or exposed.……Including: rubber cable, welding cable, URD cable, XLPE insulated power calbe etc.

  • Bare Overhead Conductor

    Bare Overhead Conductor

    Bare Overhead Conductors are used in overhead transmission and distribution network applications.They are also used for un-insulated hook ups, jumpers, grounding conductors and other applications. Our Conductors conform to ASTM, IEC, BS, BS EN and DIN standards.…… Including: AAC conductor, AAAC conductor, ACSR conductor, ACAR conductor, AACSR conductor, etc.

  • Aerial Bundled Cable

    Aerial Bundled Cable

    Aerial bundled cables (also aerial bundled conductors or simply ABC) are overhead power lines using several insulated phase conductors bundled tightly together, usually with a bare neutral conductor. Our abc calbe conform to ASTM, IEC, SANS standards.……Including: abc cables, cvered line wire, service drop wire etc.

  • LV 3 core Cu/Al conductor armoured power cablesLV 3 core Cu/Al conductor armoured power cables are used for the power and control circuit, the cable steel wire armored play good protective effect. So it can be used for building interior or buried underground.
     
    Structure:
    Conductor: solid aluminum or copper conductor, 2 types circular or fan, follow the 6360/IEC BS 60228
     
    Insulated: XLPE (XLPE) GP 8 GP or ethylene propylene rubber 6 class
     
    Color coded 1 Core: Brown
    2 Core: brown or blue
    3 core: Brown, black, gray
    4 core: blue, brown, black, gray
    5 core: yellow green, blue, brown, black, gray
    More than 5 cores: white line core and black digital logo
     
    Inner: PVC (polyvinyl chloride)
     
    Armoured: single core: AWA (aluminium wire armour)
     
    Multi core: SWA (steel wire armored)
     
    Outer sheath PVC (polyvinyl chloride), or anti mouse PVC (optional)
    LV 3 core Cu/Al conductor armoured power cables
    Technical parameter:
     
    Rated voltage: 600/1000V
     
    Rated temperature 0°C to 90°C
     
    Bending radius: 1.5mm2 – to 16mm2: 6 x diameter
     
    25mm2 – and above: 8 x diameter
     
    Fireproofing: IEC60332 the first part, the first part of BS4066
     
    Technical parameter:
     
    600/1000V three conductor multistrand copper conductor power cable parameter:
     
    Nominal conductor cross-sectional area Stranded type Nominal thickness of insulation Nominal lining thickness Nominal steel wire armoured diameter Nominal sheath thickness Nominal diameter Nominal weight
    Extrusion type lining Tape lined
    mm² No./mm mm mm mm mm mm mm kg/km
    3×1.5 7/0.53 0.6 0.8 0.9 1.3 12.6 340
    3×2.5 7/0.67 0.7 0.8 0.9 1.4 14.1 408
    3×4 7/0.85 0.7 0.8 0.9 1.4 15.3 498
    3×6 7/1.04 0.7 0.8 0.9 1.4 16.6 600
    3×10 7/1.35 0.7 0.8 1.25 1.5 19.5 915
    3×16 7/1.70 0.7 0.8 1.25 1.6 21.6 21.6 1130
    3×25 7/2.14 0.9 1 1.6 1.7 26.7 26.3 1710
    3×25* 7/2.14 0.9 1 1.6 1.7 23.6 23.2 1710
    3×35 7/2.52 0.9 1 1.6 1.8 29.4 29.0 2100
    3×35* 7/2.52 0.9 1 1.6 1.8 25.7 25.3 2100
    3×50* 19/1.78 1.0 1 1.6 1.8 28.5 28.1 2450
    3×70* 19/2.14 1.1 1 1.6 1.9 32.2 31.8 3120
    3×95* 19/2.52 1.1 1.2 2.0 2.1 37.0 36.2 4310
    3×120* 37/2.03 1.2 1.2 2.0 2.2 40.4 39.6 5160
    3×150* 37/2.25 1.4 1.4 2.5 2.3 45.5 44.3 7160
    3×185* 37/2.52 1.6 1.4 2.5 2.4 49.8 48.6 8600
    3×240* 61/2.25 1.7 1.4 2.5 2.6 55.1 53.9 10755
    3×300* 61/2.52 1.8 1.6 2.5 2.7 60.2 58.6 13080
    3×400* 61/2.85 2 1.6 2.5 2.9 66.6 65.0 15810
     
    600/1000V three conductor solid aluminum conductor power cable parameter:
     
    Nominal conductor cross-sectional area Nominal thickness of insulation Nominal thickness of lining Nominal diameter aluminium wire armoured Armoured tape Nominal sheath thickness Nominal diameter Nominal cable weight
    thickness width Aluminium wire armoured Aluminium strip armoured
    Extrusion type lining tape lined
    mm² mm mm mm mm mm mm mm mm mm kg/km
    3×16 0.7 0.8 1.25 0.6 2.4 1.6 20.3 20.3 19 760
    3×25 0.9 1 1.6 0.6 2.4 1.7 22.5 22.1 20.1 1020
    3×25* 0.9 1 1.6 0.6 2.4 1.7 24.9 24.5 22.5 1020
    3×35 0.9 1 1.6 0.6 2.4 1.8 24.4 24.9 22 1200
    3×35* 0.9 1 1.6 0.6 2.4 1.8 27.3 26.9 24.9 1200
    3×50* 1.0 1 1.6 0.6 2.4 1.8 26.8 26.4 24.9 1380
    3×70* 1.1 1 1.6 1 3.6 1.9 30.2 29.8 28.6 1750
    3×95* 1.1 1.2 2.0 1 3.6 2.1 34.8 34.0 32 2420
    3×120* 1.2 1.2 2.0 1.4 4.8 2.2 37.8 37.0 35.8 2820
    3×150* 1.4 1.4 2.5 1.4 4.8 2.3 42.7 41.5 39.3 3660
    3×185* 1.6 1.4 2.5 1.4 4.8 2.4 46.7 45.5 43.3 4350
    3×240* 1.7 1.4 2.5 1.4 4.8 2.6 51.5 50.3 48.1 5220
    3×300* 1.8 1.6 2.5 1.8 6.4 2.7 56.2 54.6 53.2 6200