JYTOP XLPE POWER CABLE

phone

ht xlpe cable specification

Leave a Reply

Your email address will not be published. Required fields are marked *

  • Power Cable

    Power Cable

    Power cables are mainly used for power transmission and distribution purpose. It is an assembly of one or more individually insulated electrical conductors, usually held together with an overall sheath. The assembly is used for transmission and distribution of electrical power. Electrical power cables may be installed as permanent wiring within buildings, buried in the ground and run overhead or exposed.……Including: rubber cable, welding cable, URD cable, XLPE insulated power calbe etc.

  • Bare Overhead Conductor

    Bare Overhead Conductor

    Bare Overhead Conductors are used in overhead transmission and distribution network applications.They are also used for un-insulated hook ups, jumpers, grounding conductors and other applications. Our Conductors conform to ASTM, IEC, BS, BS EN and DIN standards.…… Including: AAC conductor, AAAC conductor, ACSR conductor, ACAR conductor, AACSR conductor, etc.

  • Aerial Bundled Cable

    Aerial Bundled Cable

    Aerial bundled cables (also aerial bundled conductors or simply ABC) are overhead power lines using several insulated phase conductors bundled tightly together, usually with a bare neutral conductor. Our abc calbe conform to ASTM, IEC, SANS standards.……Including: abc cables, cvered line wire, service drop wire etc.

  • XLPE  Insulated Power Cable  is used to transmit and distribute power for the power transmission and distribution system 35 KV or lower. It is generally applied in the fields of power , construction, mine, metallurgy , petrochemical industry and communication. It completely replaces the oil immersed paper insulated power cable and partially replaces the PVC insulated power cable.
     
    Construction
     
    Copper or aluminium conductor
    XLPE insulation
    Copper tape or copper wire screen
    Galvanized steel wire or tape armored
    PVC or PE sheath
     
    10KV YJV22-3*35 high voltage copper conductor power cable parameter:
     
    Nominal cross section conductor Insulation thickness Sheath thickness Cable approximate diameter Cable approximate weight 20℃
    Conductor
    Cable current carrying capacity Short circuit current
    Dc resistance in the air direactly buired in the soil Conductor shield layer
    Copper tape Copper wire
    mm 2 mm mm mm kg/km Ω/km A A KA KA KA
    3×25 3.4 2.4 48 3190 0.727 120 125 3.69 2.958
    3×35 3.4 2.5 50 3731 0.524 140 155 5.15 2.958
    3×50 3.4 2.6 53 4396 0.387 165 180 7.31 2.958
    3×70 3.4 2.7 57 5198 0.268 210 220 10.2 2.958
    3×95 3.4 2.9 62 6350 0.193 355 265 13.8 2.958
    3×120 3.4 3 65 7257 0.153 290 300 17.4 2.958
    3×150 3.4 3.1 69 8383 0.124 330 340 21.7 2.958
    3×185 3.4 3.2 72 9741 0.0991 375 380 26.7 2.958
    3×240 3.4 3.3 78 11854 0.0754 435 435 34.6 3.301
    3×300 3.4 3.4 84 14861 0.0601 495 485 43.1 3.301
     
    Selecting the correct type and size of these cables for the desired application is an important task for any electrical project, because the performance of all equipment largely depends upon the performance of the cables. Apart from the technical suitability and conformance, the cost of equipment has become another important aspect while purchasing these cables. The designers and consultants constantly keep their focus on economically viable proposals in selecting the equipment. Selecting the correct type and size of cable not only ensures the trouble free performance, but also optimizes the cost of equipment, installation and other operation as well.
     
    These high tensions XLPE cables are meant for withstanding high voltages under extreme electrical conditions.
     
    More information, please contact us by E-mail: [email protected]
     

    Pre:
    Next: Difference between single core and multicore cable with same cross-sectional area