JYTOP XLPE POWER CABLE

phone

BS6622 MV single core armoured 33kv xlpe cable with strands copper conductor

Leave a Reply

Your email address will not be published. Required fields are marked *

  • Power Cable

    Power Cable

    Power cables are mainly used for power transmission and distribution purpose. It is an assembly of one or more individually insulated electrical conductors, usually held together with an overall sheath. The assembly is used for transmission and distribution of electrical power. Electrical power cables may be installed as permanent wiring within buildings, buried in the ground and run overhead or exposed.……Including: rubber cable, welding cable, URD cable, XLPE insulated power calbe etc.

  • Bare Overhead Conductor

    Bare Overhead Conductor

    Bare Overhead Conductors are used in overhead transmission and distribution network applications.They are also used for un-insulated hook ups, jumpers, grounding conductors and other applications. Our Conductors conform to ASTM, IEC, BS, BS EN and DIN standards.…… Including: AAC conductor, AAAC conductor, ACSR conductor, ACAR conductor, AACSR conductor, etc.

  • Aerial Bundled Cable

    Aerial Bundled Cable

    Aerial bundled cables (also aerial bundled conductors or simply ABC) are overhead power lines using several insulated phase conductors bundled tightly together, usually with a bare neutral conductor. Our abc calbe conform to ASTM, IEC, SANS standards.……Including: abc cables, cvered line wire, service drop wire etc.

  • BS6622 MV single core armoured 33kv xlpe cable with strands copper conductorType: British standard medium voltage power cable – BS 6622 single core armored 33KV XLPE insulated stranded copper conductor cable
     
    Voltage level: medium and low voltage power cables (35KV and below)
     
    Wire core material: bare copper wire
     
    Insulating materials: oil impregnated paper insulated power cable
     
    Product certification: BS
     
    Sheath material: cross linked polyethylene(XLPE)
     
    Nominal section: 50-1000 mm2
     
    Maximum diameter of wire: 64.2 mm
     
    Core number: 1
     
    Installation parameter:
    Cross-sectional area
    mm2
    Nominal weight
    kg/m
    Every axis length
    m
    Minimum bending radius
    mm
    Pipe diameter
    mm
    50 2.1 1000 850 100
    70 2.4 500 900 100
    95 2.7 500 950 100
    120 3.1 500 950 100
    150 3.6 500 1000 100
    185 4.0 500 1050 100
    240 4.7 500 1100 100
    300 5.5 500 1150 100
    400 6.4 250 1250 100
    500 7.6 250 1300 125
    630 9.1 250 1350 125
    800  
     
    Power performance:
     
    Cross-sectional area
    mm2
    20 ℃  Conductor dc resistance
    uohms/m
    90 ℃Conductor Ac resistance
    uohms/m
    50Hz reactance
    uohms/m
    50Hz  impedance
    uohms/m
    Capacitance
    PF/m
    Under the normal voltage and frequency of charging current
    mA/m
    50 387 494 160 578 138 0.83
    70 268 343 151 374 154 0.92
    95 193 248 143 285 169 1.01
    120 153 196 137 239 183 1.10
    150 124 159 135 207 194 1.16
    185 99.1 128 130 181 210 1.26
    240 75.4 98 125 158 229 1.37
    300 60.1 80 121 144 249 1.49
    400 47.0 64 116 132 273 1.64
    500 36.6 51 113 123 298 1.79
    630 28.3 42 108 115 327 1.96
    800  