  • Power Cable

    Power Cable

    Power cables are mainly used for power transmission and distribution purpose. It is an assembly of one or more individually insulated electrical conductors, usually held together with an overall sheath. The assembly is used for transmission and distribution of electrical power. Electrical power cables may be installed as permanent wiring within buildings, buried in the ground and run overhead or exposed.……Including: rubber cable, welding cable, URD cable, XLPE insulated power calbe etc.

  • Bare Overhead Conductor

    Bare Overhead Conductor

    Bare Overhead Conductors are used in overhead transmission and distribution network applications.They are also used for un-insulated hook ups, jumpers, grounding conductors and other applications. Our Conductors conform to ASTM, IEC, BS, BS EN and DIN standards.…… Including: AAC conductor, AAAC conductor, ACSR conductor, ACAR conductor, AACSR conductor, etc.

  • Aerial Bundled Cable

    Aerial Bundled Cable

    Aerial bundled cables (also aerial bundled conductors or simply ABC) are overhead power lines using several insulated phase conductors bundled tightly together, usually with a bare neutral conductor. Our abc calbe conform to ASTM, IEC, SANS standards.……Including: abc cables, cvered line wire, service drop wire etc.

  • British standard BS 6883 swa flexible cable colours

    Armoured power flexible cable is suitable for installation in mechanical maintenance ship or offshore. A series of size artificial common cable can be used to control and power equipment. This kind of cable applies equally the masses and instrument shore in case of a fire.
     
    Rated voltage 0.6/1kV
     
    Conductor BS6360 2 class or 5 class conductor
    (5 types are usually required to make)
     
    Rated temperature 90°C maximum conductor temperature
     
    Static rated temperature -30°C to 90°C
    The bending radius (static) ≤25 mm2 – 4 x cable diameter
     
    >25 mm2 – 6 x cable diameter
     
    Flame retardant part 3A BS4066, part 3A IEC60332
     
    Color coding:
     
    A) color coding
     
    1 core red or black
     
    2 core red, black
     
    3 core red, yellow, blue
     
    4 core red, yellow, blue, black
     
    5 core and above, in sequence coding

    Technical parameter:
     
    Conductor nominal cross-sectional area
    (mm2/font)
    Inner sheath outer diameter
    min-max mm
    Outer sheath diameter
    min-max mm
    Single core cable
    1 4.7 – 5.8 8.3 – 9.8
    1.5 5.0 – 6.2 8.5 – 10.1
    2.5 5.4 – 6.6 8.9 – 10.5
    4 6.3 – 7.6 9.8 – 11.7
    6 6.8 – 8.1 10.4 – 12.2
    10 7.7 – 9.1 11.5 – 13.4
    16 8.9 – 10.3 12.7 – 14.6
    25 11.1 – 12.8 15.0 – 17.3
    35 12.0 – 13.7 16.1 – 18.4
    50 13.7 – 15.5 17.9 – 20.2
    70 15.5 – 17.4 19.8 – 22.6
    95 17.7 – 19.8 22.2 – 25.2
    120 19.6 – 22.0 24.3 – 27.3
    150 21.6 – 24.2 26.5- 29.7
    185 24.0 – 26.6 29.8 – 33.5
    240 27.1 – 29.9 33.1 – 36.9
    300 30.0 – 33.2 36.2 – 40.1
    400 33.8 – 37.1 40.3 – 44.8
    500 37.6 – 41.1 44.5 – 49.2
    630 41.2 – 45.2 48.4 – 53.6