JYTOP XLPE POWER CABLE

phone

Common electrical cables specifications

Leave a Reply

Your email address will not be published. Required fields are marked *

  • Power Cable

    Power Cable

    Power cables are mainly used for power transmission and distribution purpose. It is an assembly of one or more individually insulated electrical conductors, usually held together with an overall sheath. The assembly is used for transmission and distribution of electrical power. Electrical power cables may be installed as permanent wiring within buildings, buried in the ground and run overhead or exposed.……Including: rubber cable, welding cable, URD cable, XLPE insulated power calbe etc.

  • Bare Overhead Conductor

    Bare Overhead Conductor

    Bare Overhead Conductors are used in overhead transmission and distribution network applications.They are also used for un-insulated hook ups, jumpers, grounding conductors and other applications. Our Conductors conform to ASTM, IEC, BS, BS EN and DIN standards.…… Including: AAC conductor, AAAC conductor, ACSR conductor, ACAR conductor, AACSR conductor, etc.

  • Aerial Bundled Cable

    Aerial Bundled Cable

    Aerial bundled cables (also aerial bundled conductors or simply ABC) are overhead power lines using several insulated phase conductors bundled tightly together, usually with a bare neutral conductor. Our abc calbe conform to ASTM, IEC, SANS standards.……Including: abc cables, cvered line wire, service drop wire etc.

  • Copper (aluminum) core PVC insulation and sheath fixed laying cable (wire):
    bv – copper core PVC insulated cables (wires)
    BLV- al core PVC insulated cables (wires)
    BVR- copper core PVC insulated cables (wires)
    BVV- copper core PVC insulated and sheathed round cable (wire)
    BLVV- aluminium core PVC insulated and sheathed round cable (wire)
    BVVB- copper conductor PVC insulated and sheathed flat cable (wire)
    BLVVB- aluminum conductor PVC insulated and sheathed flat cable (wire)
    BV-90- copper core heat resistant 90℃
    This product is suitable for AC rated voltage U/U0 450/750V and below the power, lighting, household electrical appliances, instruments and meters and telecommunications equipment copper or aluminum core PVC insulated cables (wires)
     
    Low smoke halogen free cable products:
    The common cable specifications: low smoke halogen-free flame retardant cable series, WDZ- (cable wire code and common type)
    Note: flame retardant A, B, general C, D, for example: WDZA-YJY WDZB-YJV23 WDZC-BY WDZ-BVY WDZD-VY WDZB-KYJY WDZC-KVV23 (for fixed soft cable for mobile) laying in rated AC the U0/U voltage 35kV and below the room, cable bridge, cable pipeline transmission and distribution power line fixed occasions, mainly used in high-rise buildings, hospitals, theaters, power station, subway, tunnel, ship, offshore oil platform, radio and Television Center, computer center and other crowded space, closed places, rated voltage of cables shall not be less than the nominal voltage of the power supply system.
     
    10kV and 1kV copper (aluminum) core cross linked polyethylene insulated overhead cables:
    JKYJ, JKLYJ – copper (aluminum) core cross-linked polyethylene insulated overhead cable
    JKY, JKLY – copper (aluminum) core cross-linked polyethylene insulated overhead cable
    JKV, JKLV – copper (aluminum) core PVC insulated overhead cable (only for 1kV)
    For fixed installation in AC rated voltage U0 / u kV and 10kV indoor and outdoor overhead transmission power line used can be used for single-phase grounding fault each time less than 1min system, can be used for the longest time less than 8h, per year does not exceed the total 125h system.
     
    Copper (aluminium) core PVC insulated and sheathed power cable:
    VLV, VV one copper (aluminum) core PVC insulated, PVC sheathed power cable
    VLV, VV one copper (aluminum) core PVC insulated, PE sheathed power cable
    For the installation of the rated AC voltage UO/U of 0.6/1KV and below the indoor, overhead, cable trench, pipeline transmission and distribution of power lines with.
    1 Core: 1.5–630mm
    2 Core: 2*1.5–2*185mm
    3 core: 3*1.5-3*300mm
    4 core: 4*4-4*300mm
    31 core: 1*2.5-3*300 1*150mm 3*4
    32 core: 1*2.5-3*300 2*150mm 3*4
    41 core: 1*2.5-4*300 1*150mm 4*4
     
    Copper core PVC insulated PVC sheathed (armoured) control cable:
    KVV- copper conductor PVC insulated, PVC sheathed control cable
    KVV22- copper core PVC insulated, steel tape armoured, PVC sheathed control cable
    KVVP2- copper core PVC insulated PE sheathed copper shielded control cable
    KVVP- copper conductor, PVC insulated, PE sheathed, braided shield control cable
     
    This product is suitable for AC rated voltage 450/750V and below, power station, substation, mining, petrochemical enterprises single control or unit equipment control.
     
    Copper core PVC insulated PVC sheathed fire (armoured) wire and cable:
    NH-2271EC01 (BV) -450/750V copper core PVC insulated wire
    NH-BVV-[NH-2271EC10 (BVV)]-300/500V copper core PVC insulated and sheathed flame retardant wire
    NH-VV-0.6/1KV copper conductor PVC insulated and sheathed fire resistant power cable
    NH-VV22-0.6/1KV copper core PVC insulated and sheathed fire-resistant power cable
    NH-KVV-450/750V copper conductor, PVC insulated, PVC sheathed fire-resistant control cable
    NH-VV22-450/750V copper conductor, PVC insulated, steel tape armoured PVC sheathed fire-resistant control cable
    This product is used in the AC rated voltage 0.6/1KV and below PVC insulated fire resistant cable, it can be used in the fire prone areas in the case of fire, still can maintain a certain time to continue run.
     
    Cross linked polyethylene insulated power cable:
    YJLV YJY copper (aluminum) core cross linked polyethylene insulated, PVC sheathed power cable
    YJY22 YJLV22 copper (aluminum) core XLPE insulated PVC sheathed power cable.
    For the installation of the rated AC voltage U0/U 0.6/1kv and below the indoor cable channel, the transmission and distribution of power lines in the pipeline.
     
    Copper (aluminum) core flame retardant PVC insulated PVC sheathed (armoured) cable:
    ZR-227IEC01 (BV), ZR-BLV- copper (aluminum) core flame retardant PVC insulated wire
    ZR-BVV, ZR-BLVV, ZR-227IEC10 (BVV) – copper (aluminum) core flame retardant PVC insulated and sheathed cables (wires)
    ZR-VV, ZR-VLV- copper (aluminum) core flame retardant PVC insulated and sheathed power cable
    ZR-VV22, ZR-VLV22- copper (aluminum) core flame retardant PVC insulated steel armoured and PVC sheathed power cables
    ZR-KVV- copper conductor, flame-retardant PVC insulated PVC sheathed control cable
    ZR-KVV2- copper core PVC insulated PVC sheathed control cable

    Henan Jiapu Cable is the professional wire and cable manufacturer in China, we not only can supply the above power cables, but also can provide other types cable products. If you have any need or any queastion about wire & cable, please contact us by E-mail: [email protected]
     

    Pre:
    Next: IEC 60502 standard 3 core electric cable