JYTOP XLPE POWER CABLE

phone

4c cable 70mm pvc – 4*70mm2 PVC power cable

Leave a Reply

Your email address will not be published. Required fields are marked *

  • Power Cable

    Power Cable

    Power cables are mainly used for power transmission and distribution purpose. It is an assembly of one or more individually insulated electrical conductors, usually held together with an overall sheath. The assembly is used for transmission and distribution of electrical power. Electrical power cables may be installed as permanent wiring within buildings, buried in the ground and run overhead or exposed.……Including: rubber cable, welding cable, URD cable, XLPE insulated power calbe etc.

  • Bare Overhead Conductor

    Bare Overhead Conductor

    Bare Overhead Conductors are used in overhead transmission and distribution network applications.They are also used for un-insulated hook ups, jumpers, grounding conductors and other applications. Our Conductors conform to ASTM, IEC, BS, BS EN and DIN standards.…… Including: AAC conductor, AAAC conductor, ACSR conductor, ACAR conductor, AACSR conductor, etc.

  • Aerial Bundled Cable

    Aerial Bundled Cable

    Aerial bundled cables (also aerial bundled conductors or simply ABC) are overhead power lines using several insulated phase conductors bundled tightly together, usually with a bare neutral conductor. Our abc calbe conform to ASTM, IEC, SANS standards.……Including: abc cables, cvered line wire, service drop wire etc.

  • PVC cables model and name:
     
    VV ZR-VV PVC insulation and PVC sheath power cable: laying in indoor, tunnel, can not bear mechanical force effect.
     
    VV22 ZR-VV22 PVC insulation steel tape armoured PVC sheath power cable: laying in indoor, tunnel, can bear mechanical force effect.
     
    Rated voltage 0.6/1KV polyvinyl chloride insulated power cable
     
    1. Allowed working temperature of cable conductor: ≤70℃
    2. The maximum operating temperature of the cable (the longest duration does not exceed 5S): 160℃
    3. After the cable is laid, through the DC voltage 3.5KV/15min does not breakdown.
    4. In the air:
    A. single core cable in parallel when laying the center distance:
    185mm2 and the following cable diameter of 2 times; 240mm2 and above is 90mm
    B. ambient temperature: 30℃
     
    5. Direactly buried
     
    a. single core cable is not connected, the center distance is 2 times of the cable diameter.
    b. ambient temperature: 25℃
    c. soil thermal resistance coefficient: 1.0K·m/W
    d. buried depth: 0.7m
     
    VV(VV22) copper core pvc insulation pvc sheath power cable (0.6/1KV) technical parameter:
    4*70mm2 PVC power cable

    Pre:
    Next: Leader cable basic structure and catalogue