    Power Cable

    Power cables are mainly used for power transmission and distribution purpose. It is an assembly of one or more individually insulated electrical conductors, usually held together with an overall sheath. The assembly is used for transmission and distribution of electrical power. Electrical power cables may be installed as permanent wiring within buildings, buried in the ground and run overhead or exposed.……Including: rubber cable, welding cable, URD cable, XLPE insulated power calbe etc.

  • Bare Overhead Conductor

    Bare Overhead Conductor

    Bare Overhead Conductors are used in overhead transmission and distribution network applications.They are also used for un-insulated hook ups, jumpers, grounding conductors and other applications. Our Conductors conform to ASTM, IEC, BS, BS EN and DIN standards.…… Including: AAC conductor, AAAC conductor, ACSR conductor, ACAR conductor, AACSR conductor, etc.

  • Aerial Bundled Cable

    Aerial Bundled Cable

    Aerial bundled cables (also aerial bundled conductors or simply ABC) are overhead power lines using several insulated phase conductors bundled tightly together, usually with a bare neutral conductor. Our abc calbe conform to ASTM, IEC, SANS standards.……Including: abc cables, cvered line wire, service drop wire etc.

  • 3 core outdoor cable
    The products are manufactured according to the standard of GB12706 or IEC, BS, DIN and ICEA upon requirement. Widely used in power transmission and distribution lines with rated power frequency voltage 3.6-6 KV ~ 19-33KV.
     
    Standard:
    iec 60502 part 1 (1.8 / 3kv)
    iec 60502 part 2 (3.6 / 6kv to 18 / 30kv)
     
    Operational performance:
    Standards: BS5467, Flame propagation to BS EN 60332
    Conductor: Stranded Plain Annealed Copper Conductors.
    Insulation: XLPE
    Insulation Colours: Black
    Bedding: PVC Bedding
    Armouring: Galvanised Steel Wire Armour.
    Sheath: PVC
    Sheath Colour: Black
    Voltage Rating: 600/1000 volts
    Temperature Rating: -15°C to 90°C
    Minimum Bending Radius: 6 x overall diameter
     
    The rated voltage of the cable for a given applixation shall be suitable for the operating conditions in the system in which the cable is used,and is expressed in the form of U0/U(Um)kv Where:
    U0-The rated power-frequency voltage between conductors and earth metallic screen ,for which the cable designed;
    U - The rated power-frequency voltage between conductos, for which the cable designed;
    Um- The maximum value of the“highest system voltage”for which the equipment may beused.
     
    XLPE or EPR/HEPR insulation thickness:
    Nominal cross-sectional area

     

    Under the nominal voltage the insulation thickness
    1.8/3kV
    (Um=3.6)kV
    3.6/6kV
    (Um=7.2)kV
    6/10KV
    (Um=12KV)
    8.7/15KV
    (Um=17KV)
    12/20KV
    (Um=24KV)
    18/30KV
    (Um=36KV)
    21/35KV
    (Um=42KV)
    26/35KV
    (Um=42KV)
    mm2 mm mm mm mm mm mm mm mm

     

    XLPE/EPR XLPE EPR XLPE/EPR XLPE/EPR XLPE/EPR XLPE/EPR XLPE/EPR XLPE/EPR
       unscreened shielding
    10 2.0 2.5 3.0 2.5
    16 2.0 2.5 3.0 2.5 3.4
    25 2.0 2.5 3.0 2.5 3.4 4.5
    35 2.0 2.5 3.0 2.5 3.4 4.5 5.5
    50 – 185 2.0 2.5 3.0 2.5 3.4 4.5 5.5 8.0 9.3 10.5
    240 2.0 2.6 3.0 2.6 3.4 4.5 5.5 8.0 9.3 10.5
    300 2.0 2.8 3.0 2.8 3.4 4.5 5.5 8.0 9.3 10.5
    400 2.0 3.0 3.0 3.0 3.4 4.5 5.5 8.0 9.3 10.5
    500 – 1600 2.2-2.8 3.2 3.2 3.2 3.4 4.5 5.5 8.0 9.3 10.5
     
    Round steel wire armoured cable diameter:
    Armoured layer virtual diameter Armoured cable diameter
    mm mm
    > <  
    10 1.25
    10 15 1.25
    15 25 1.6
    25 35 2.0
    35 60 2.5
    60 3.15

    YJV22 three core XLPE insulation steel tape armored power cable technology parameters:

    Nominal cross section (mm 2)

    Nominal thickness of insulation (mm)

    Approximate diameter (mm)

    Approximate weight (kg/km)

    YJV 22

    YJLV 22

    25 
    35 
    50 
    70 
    95 
    120 
    150 
    185 
    240 
    300

    4.5 
    4.5 
    4.5 
    4.5 
    4.5 
    4.5 
    4.5 
    4.5 
    4.5 
    4.5

    50.8 
    53.2 
    56.4 
    60.3 
    64.1 
    69.5 
    73.1 
    76.9 
    82.3 
    88.6

    3403 
    3887 
    4509 
    5419 
    6441 
    7790 
    8964 
    10314 
    12402 
    15485

    2906 
    3182 
    3565 
    4085 
    4598 
    5398 
    5977 
    6649 
    7656 
    9588